Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Medicine (Baltimore) ; 103(15): e37748, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608106

RESUMO

We aimed to investigate the accuracy of proton density fat fraction (PDFF) measurement of the lumbar vertebral bone marrow using chemical shift-encoded magnetic resonance imaging (CSE-MRI) with compressed sensing combined with parallel imaging (CSPI). This study recruited a commercially available phantom, and 43 patients. Fully sampled data without CSPI and under-sampled data with CSPI acceleration factors of 2.4, 3.6, and 4.8 were acquired using a 1.5T imaging system. The relationships between PDFF measurements obtained with the no-CSPI acquisition and those obtained with each CSPI acquisition were assessed using Pearson correlation coefficient (r), linear regression analyses, and Bland-Altman analysis. The intra- and inter-observer variabilities of the PDFF measurements were evaluated using the intraclass correlation coefficient. PDFF measurements obtained with all acquisitions showed a significant correlation and strong agreement with the reference PDFF measurement of the phantom. PDFF measurements obtained using CSE-MRI with and without CSPI were positively correlated (all acquisitions: r = 0.99; P < .001). The mean bias was -0.31% to -0.17% with 95% limits of agreement within ±2.02%. The intra- and inter-observer agreements were excellent (intraclass correlation coefficient: 0.988 and 0.981, respectively). A strong agreement and positive correlation were observed between the PDFF measurements obtained using CSE-MRI with and without CSPI. PDFF measurement of the lumbar vertebral bone marrow using CSE-MRI with CSPI can be acquired with a maximum reduction of approximately 75% in the acquisition time compared with a fully sampled acquisition.


Assuntos
Medula Óssea , Prótons , Humanos , Medula Óssea/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas
2.
J Magn Reson Imaging ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38174771

RESUMO

BACKGROUND: Osteoporosis with low trabecular bone quality (OLB) in patients with breast cancer receiving aromatase inhibitor (AI) therapy is associated with an increased risk of vertebral fractures. The capability of chemical shift-encoded MRI (CSE-MRI) in detecting OLB needs to be investigated. PURPOSE: To assess the diagnostic performance of proton density fat fraction (PDFF) and R2* measurements from CSE-MRI for detecting OLB in postmenopausal women with breast cancer undergoing AI therapy. STUDY TYPE: Prospective. POPULATION: 126 postmenopausal females (mean age: 69.5 ± 8.8 years) receiving AIs (average period: 41.6 ± 26.5 months) after breast cancer surgery. FIELD STRENGTH/SEQUENCE: 1.5-T, three-dimensional CSE-MRI (six echoes), T1-weighted Dixon, short tau inversion recovery, and diffusion-weighted images. ASSESSMENT: Both CSE-MRI and dual-energy x-ray absorptiometry were performed on the same day. Measurements included averaged PDFF, R2*, bone mineral density (BMD), and trabecular bone score (TBS) from L1 to L4 vertebrae. A T-score ≤ -2.5 from BMD measurements indicated osteoporosis, whereas T-scores of ≤ - 2.5 plus TBS ≤-3.7 indicated OLB. The diagnostic performance of PDFF, R2*, and the combination of PDFF and R2* for identifying osteoporosis or OLB was assessed. STATISTICAL TESTS: Student's t-test; Mann-Whitney U test; χ2 or Fisher exact tests; Pearson correlation; multivariate analysis; Receiver operating characteristic (ROC) analysis with the area under the curve (AUC); logistic regression model; intraclass correlation coefficient. A P-value <0.05 was considered statistically significant. RESULTS: For detecting osteoporosis, AUC values were 0.59 (PDFF), 0.66 (R2*), and 0.65 (combined PDFF and R2*). Significant mean differences were noted between patients with and without OLB for PDFF (66.11 ± 5.36 vs. 57.49 ± 6.43) and R2* (46.62 ± 9.24 vs. 63.36 ± 12.44). AUC values for detecting OLB were 0.75 (PDFF), 0.82 (R2*), and 0.84 (combined PDFF and R2*). DATA CONCLUSION: R2* may perform better than PDFF for identifying OLB in patients with breast cancer receiving AIs. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 4.

3.
Medicine (Baltimore) ; 99(47): e23138, 2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33217817

RESUMO

We have developed a deep learning-based approach to improve image quality of single-shot turbo spin-echo (SSTSE) images of female pelvis. We aimed to compare the deep learning-based single-shot turbo spin-echo (DL-SSTSE) images of female pelvis with turbo spin-echo (TSE) and conventional SSTSE images in terms of image quality.One hundred five and 21 subjects were used as training and test sets, respectively. We performed 6-fold cross validation. In the training process, low-quality images were generated from TSE images as input. TSE images were used as ground truth images. In the test process, the trained convolutional neural network was applied to SSTSE images. The output images were denoted as DL-SSTSE images. Apart from DL-SSTSE images, classical filtering methods were adopted to SSTSE images. Generated images were denoted as F-SSTSE images. Contrast ratio (CR) of gluteal fat and myometrium and signal-to-noise ratio (SNR) of gluteal fat were measured for all images. Two radiologists graded these images using a 5-point scale and evaluated the image quality with regard to overall image quality, contrast, noise, motion artifact, boundary sharpness of layers in the uterus, and the conspicuity of the ovaries. CRs, SNRs, and image quality scores were compared using the Steel-Dwass multiple comparison tests.CRs and SNRs were significantly higher in DL-SSTSE, F-SSTSE, and TSE images than in SSTSE images. Scores with regard to overall image quality, contrast, noise, and boundary sharpness of layers in the uterus were significantly higher on DL-SSTSE and TSE images than on SSTSE images. There were no significant differences in the CRs, SNRs, and respective scores between DL-SSTSE and TSE images. The score with regard to motion artifacts was significantly higher on DL-SSTSE, F-SSTSE, and SSTSE images than on TSE images. The score with regard to the conspicuity of ovaries was significantly higher on DL-SSTSE images than on F-SSTSE, SSTSE, and TSE images (P < .001).DL-SSTSE images showed higher image quality as compared with SSTSE images. In comparison with conventional TSE images, DL-SSTSE images had acceptable image quality while keeping the advantage of the motion artifact-robustness and acquisition time efficiency in SSTSE imaging.


Assuntos
Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Pelve/diagnóstico por imagem , Melhoria de Qualidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
4.
Gan To Kagaku Ryoho ; 47(13): 1845-1847, 2020 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-33468848

RESUMO

A 42-year-old man complaining of left back pain was admitted to our hospital. The hepatis B and C surface antigens were negative. The serum levels of tumor markers were within the reference ranges. Abdominal ultrasound revealed an 8 cm-sized, primarily round and hyperechoic mass in the left lateral segment. Contrast-echo showed non-uniform enhancement in the arterial phase and uniform enhancement in the portal phase. This mass did not indicate"wash-out"on contrast- enhanced CT. It showed hypointensity in the hepatobiliary phase on MRI. The definitive diagnosis could not be obtained, and the patient was suspected with malignancy, such as hepatocellular carcinoma(HCC). Therefore, left hemi-hepatectomy was performed for the diagnostic treatment. Based on the immunochemical staining results, he was diagnosed with angiomyolipoma( AML). AML is composed of fat, blood vessels, and smooth muscles. It is regarded as a tumor of perivascular epithelioid cell tumor(PEComa). Early venous return and adipose tissues in the tumor were the distinctive features of this tumor. The preoperative diagnosis of AML without any fatty component as in this case is very difficult.


Assuntos
Angiomiolipoma , Carcinoma Hepatocelular , Neoplasias Renais , Neoplasias Hepáticas , Adulto , Angiomiolipoma/diagnóstico por imagem , Angiomiolipoma/cirurgia , Carcinoma Hepatocelular/cirurgia , Hepatectomia , Humanos , Neoplasias Hepáticas/cirurgia , Masculino
5.
Br J Radiol ; 93(1105): 20190003, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31738082

RESUMO

OBJECTIVE: This study aimed to assess and compare the diagnostic performance of the coronary artery to aortic luminal attenuation ratio (CAR), transluminal attenuation gradient (TAG), and corrected coronary opacification (CCO) difference on coronary CT angiography (cCTA) for detecting haemodynamically significant coronary artery stenosis. METHODS: 33 patients who underwent cCTA, gated SPECT myocardial perfusion imaging (MPI), and invasive coronary angiography within 3 months were included in this retrospective study. The degree of coronary stenosis on cCTA was visually assessed in all patients. Additionally, CAR, TAG, and CCO difference were analyzed and calculated in all patients. Haemodynamically significant coronary stenosis was defined as a vessel with ≥50% luminal stenosis on invasive coronary angiography and an associated abnormal perfusion defect on MPI in the same territory. Diagnostic performance was assessed on a per-vessel basis by the area under the receiver operating characteristic (ROC) curve (AUC). RESULTS: Among 99 vessels, 12 were excluded and the remaining 87 were analyzed. 17 (19.5%) vessels were determined as haemodynamically significant coronary artery stenosis. On ROC analysis, the AUC was 0.71 for cCTA, 0.80 for CAR, 0.61 for TAG, 0.74 for CCO, 0.87 for combined CAR and cCTA, 0.77 for combined TAG and cCTA, and 0.75 for combined CCO and cCTA. The AUC for combined CAR and cCTA was significantly greater compared with cCTA alone (p < 0.01). CONCLUSION: Non-invasive CAR derived from 64-detector row CT was feasible and might be helpful for the detection of haemodynamically significant coronary artery stenosis. Still, further investigations such as intra- and inter-reader correlation, evaluation of larger numbers in different settings, and time efficiency are required for applying CAR in various situations. ADVANCES IN KNOWLEDGE: CAR could be used as novel noninvasive technique to detect haemodynamically significant coronary artery stenosis.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Idoso , Aorta Torácica/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
6.
Jpn J Radiol ; 35(8): 463-471, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28540464

RESUMO

PURPOSE: This study aimed to compare the detectability of neoplastic lesion enhancement after gadolinium-based contrast media injection in three-dimensional T1-weighted black blood Cube (3D-T1W BB Cube) and three-dimensional T1-weighted fast spoiled gradient-echo (3D-T1W fast SPGR) images obtained with 1.5-T magnetic resonance imaging (MRI). MATERIALS AND METHODS: Phantom and clinical studies were performed to compare the lesion detectability and contrast ratio (CR) between 3D-T1W BB Cube and 3D-T1W fast SPGR pulse sequences. RESULTS: In the phantom study, the CRs for 3D-T1W BB Cube and 3D-T1W fast SPGR were equivalent at low gadolinium concentrations (0.125-1.25 mmol/l). In the clinical study, the detectability in the two modalities was similar for enhanced lesions ≥5 mm, but was significantly better in 3D-T1W BB Cube for lesions <5 mm (p = 0.011). Similarly, the CRs in both modalities were similar for lesions ≥5 mm (0.66 ± 0.36 vs. 0.56 ± 0.30, p = 0.153), but significantly lower in 3D-T1W BB Cube images for lesions <5 mm (0.29 ± 0.19 vs. 0.39 ± 0.21, p = 0.006). CONCLUSIONS: Contrast 3D-T1W BB Cube imaging appears more sensitive than 3D-T1W fast SPGR imaging for detecting neoplastic lesion enhancement in the clinical setting using a 1.5-T MRI scanner, particularly for lesions <5 mm in diameter.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Sensibilidade e Especificidade
7.
Eur Radiol ; 25(11): 3175-86, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25929942

RESUMO

OBJECTIVES: The purpose of this study was to investigate the usefulness of T1W black-blood Cube (BB Cube) and T1W BB Cube fluid-attenuated inversion recovery (BB Cube-FLAIR) sequences for contrast-enhanced brain imaging, by evaluating flow-related artefacts, detectability, and contrast ratio (CR) of intracranial lesions among these sequences and T1W-SE. METHODS: Phantom studies were performed to determine the optimal parameters of BB Cube and BB Cube-FLAIR. A clinical study in 23 patients with intracranial lesions was performed to evaluate the usefulness of these two sequences for the diagnosis of intracranial lesions compared with the conventional 2D T1W-SE sequence. RESULTS: The phantom study revealed that the optimal parameters for contrast-enhanced T1W imaging were TR/TE = 500 ms/minimum in BB Cube and TR/TE/TI = 600 ms/minimum/300 ms in BB Cube-FLAIR imaging. In the clinical study, the degree of flow-related artefacts was significantly lower in BB Cube and BB Cube-FLAIR than in T1W-SE. Regarding tumour detection, BB Cube showed the best detectability; however, there were no significant differences in CR among the sequences. CONCLUSIONS: At 1.5 T, contrast-enhanced BB Cube was a better imaging sequence for detecting brain lesions than T1W-SE or BB Cube-FLAIR. KEY POINTS: • Cube is a single-slab 3D FSE imaging sequence. • We applied a black-blood (BB) imaging technique to T1W Cube. • At 1.5 T, contrast-enhanced T1W BB Cube was valuable for detecting brain lesions.


Assuntos
Neoplasias Encefálicas/diagnóstico , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Encéfalo/anatomia & histologia , Neoplasias Encefálicas/secundário , Circulação Cerebrovascular/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
8.
Neuroradiology ; 55(11): 1341-4, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24081813

RESUMO

INTRODUCTION: The aim of this study was to investigate the prevalence of intravertebral pneumatocyst (IVP) of the cervical spine by age group, compared with that of intradiscal vacuum (IDV). METHODS: We investigated 500 consecutive patients who underwent cervical computed tomography (CT) from May 2012 to May 2013 for various indications. CT datasets were assessed for the presence of IVPs and IDVs with stratification by age. RESULTS: IVPs of the cervical spine were detected in 8 % (7 of 86 subjects) of patients in their forties or below, 30 % (23 of 75) in their fifties, 49 % (67 of 136) in their sixties, 55 % (76 of 137) in their seventies, and 60 % (40 of 66) in their eighties or over. IDVs of the cervical spine were detected in 6, 25, 48, 54, and 57 %, respectively. Coexistence of both phenomena was identified in 4, 17, 33, 40, and 43 %, respectively. CONCLUSION: IVPs of the cervical spine are a common incidental finding, increasing in prevalence with age and more common than IDV in all age groups.


Assuntos
Cistos Ósseos/diagnóstico por imagem , Cistos Ósseos/epidemiologia , Vértebras Cervicais/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Sensibilidade e Especificidade , Adulto Jovem
9.
Acta Radiol ; 53(4): 473-7, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22422270

RESUMO

BACKGROUND: Previous literature demonstrated that the T2* value of the uterine junctional zone was lower than that of peripheral myometrium by using BOLD MR imaging. We expect T2* mapping image may add more information to T2-weighted images of the uterine myometrium. PURPOSE: To evaluate whether T2* mapping software would reproduce the result of previous report, and to apply the software to benign uterine diseases. MATERIAL AND METHODS: Five healthy volunteers and 19 patients clinically suspected of having benign pelvic disease were imaged using a 1.5T MR system. All women were of reproductive age, and all provided informed consent. Sagittal T2* images using a multishot EPI sequence were obtained. T2* values were calculated and color T2* maps reconstructed using a T2* fitting tool. RESULTS: The uterine zones could be identified in all 24 examinations on the T2* maps. In addition, a thin "4th zone" was seen between the endometrium and the JZ (junctional zone) in 19 of 24 examinations. The T2* value of JZ was significantly lower than that of peripheral myometrium (PM) (P < 0.001). No significant difference in the T2* value of the JZ or of PM was noted between normal uterus and uterus with leiomyomas and/or adenomyosis. CONCLUSION: A quantitative T2* map can easily be obtained using the PRIDE software T2* fitting tool, and the software reproduces the result from previous report. T2* value of the junctional zone was lower than that of peripheral myometrium regardless of having benign myometrial diseases.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Doenças Uterinas/diagnóstico , Adulto , Estudos de Casos e Controles , Endometriose/diagnóstico , Feminino , Humanos , Leiomioma/diagnóstico , Pessoa de Meia-Idade , Software , Estatísticas não Paramétricas
10.
Eur J Radiol ; 81(11): 2953-60, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22304982

RESUMO

PURPOSE: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). MATERIALS AND METHODS: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. RESULTS: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P=0.73), specificity (P=0.71) and accuracy (P=0.98). CONCLUSION: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.


Assuntos
Ar , Intensificação de Imagem Radiográfica/métodos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Eur J Radiol ; 81(11): 2978-83, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22305012

RESUMO

PURPOSE: The purpose of this study is to prospectively investigate the optimal dose of contrast medium for the depiction of hypervascular hepatocellular carcinoma (HCC) during the hepatic arterial phase (HAP), portal venous phase (PVP) and delayed phase (DP) of dynamic MDCT. MATERIALS AND METHODS: The study included 128 patients, out of these patients, 36 patients were found to have 56 hypervascular HCCs. Sixty-three patients were assigned to receive a dose of 525 mgI/kg with protocol A, and 62 received a dose of 630 mgI/kg with protocol B. Measurements of the attenuation values of the abdominal aorta, portal vein, hepatic vein, hepatic parenchyma and HCC during the HAP, PVP and DP were taken. Tumor-liver contrast (TLC) was calculated from the attenuation value of the hepatic parenchyma and HCC. RESULTS: The aortic attenuation value with protocol B (351, 166, and 132 HU) was significantly higher than that with protocol A (313, 153, and 120 HU) during all the phases, (P<0.01 for all phases). The hepatic enhancement from unenhanced baseline with protocol B (25.2, 63.6, 50.6 HU) was significantly higher than that with protocol A (20.2, 55.1 and 43.0 HU) during all the phases, (P<0.01 for all phases). The TLC with protocol B (37.4, -11.8 and -13.6 HU) was significantly higher than that with protocol A (28.0, -9.8 and -12.1 HU) during HAP (P=0.042). CONCLUSION: The administration of 630 mgI/kg of body weight depicts hypervascular HCC more clearly during HAP and shows sufficient hepatic enhancement of 50 HU during DP.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Aumento da Imagem/métodos , Iodo/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Carcinoma Hepatocelular/complicações , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Jpn J Radiol ; 28(2): 166-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20182853

RESUMO

We report a case of fourth ventricular mixed germ cell tumor (GCT) in a 20-year-old man. Neuroradiological investigations revealed a fourth ventricular hemorrhagic tumor with adipose tissue. We suspected mixed GCT because adipose tissue was seen preoperatively, but mixed GCT occurring after childhood in this location has not previously been reported. We describe herein the imaging findings for mixed GCT and discuss the differential diagnoses of fourth ventricular tumors with adipose tissue.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Neoplasias Encefálicas/diagnóstico , Quarto Ventrículo/diagnóstico por imagem , Quarto Ventrículo/patologia , Neoplasias Embrionárias de Células Germinativas/diagnóstico , Tecido Adiposo/cirurgia , Adulto , Biomarcadores/sangue , Biomarcadores Tumorais/sangue , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/cirurgia , Ventriculografia Cerebral/métodos , Gonadotropina Coriônica/sangue , Meios de Contraste , Diagnóstico Diferencial , Seguimentos , Quarto Ventrículo/cirurgia , Cefaleia/etiologia , Humanos , Hidrocefalia/complicações , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias Embrionárias de Células Germinativas/complicações , Neoplasias Embrionárias de Células Germinativas/cirurgia , Tomografia Computadorizada por Raios X/métodos , Vômito/etiologia , Adulto Jovem , alfa-Fetoproteínas
13.
Ann Nucl Med ; 23(4): 349-54, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19340526

RESUMO

OBJECTIVE: To investigate whether integrated fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) can differentiate benign from adrenal malignant lesions on the basis of maximum standardized uptake value (SUV(max)), tumor/liver (T/L) SUV(max) ratio, and CT attenuation value (Hounsfield Units; HU) of unenhanced CT obtained from FDG-PET/CT data. METHODS: We studied 30 patients with 35 adrenal lesions (16 adrenal benign lesions, size 16 +/- 5 mm, in 15 patients; and 19 adrenal malignant lesions, 24 +/- 12 mm, in 15 patients) who had confirmed primary malignancies (lung cancer in 23 patients, lymphoma in 2, esophageal cancer in 2, hypopharyngeal cancer in 1, prostate cancer in 1, and 1 patient in whom lesions were detected at cancer screening). All patients underwent PET/CT at 1 h post FDG injection. Diagnosis of adrenal malignant lesions was based on interval growth or reduction after chemotherapy. An adrenal mass that remained unchanged for over 1 year was the standard used to diagnose adrenal benign lesions. Values of FDG uptake and CT attenuation were measured by placing volumetric regions of interest over PET/CT images. Adrenal uptake of SUV(max) >/= 2.5 was considered to indicate a malignant lesion; SUV(max) < 2.5 was considered to indicate a benign lesion. In further analysis, 1.8 was employed as the threshold for the T/L SUV(max) ratio. Unenhanced CT obtained from PET/CT data was considered positive for adrenal malignant lesions based on a CT attenuation value >/= 10 HU; lesions with a value < 10 HU were considered adrenal benign lesions. Mann-Whitney's U test was used for statistical analyses. RESULTS: SUV(max) in adrenal malignant lesions (7.4 +/- 3.5) was higher than that in adrenal benign lesions (2.1 +/- 0.5, p < 0.05). The CT attenuation value of adrenal malignant lesions (27.6 +/- 11.9 HU) was higher than that of adrenal benign lesions (10.1 +/- 12.3 HU, p < 0.05). In differentiating between adrenal benign and malignant lesions, a CT threshold of 10 HU corresponded to a sensitivity of 57%, specificity of 94%, accuracy of 74%, positive predictive value of 92% and negative predictive value of 65%. An SUV(max) cut-off value of 2.5 corresponded to a sensitivity of 89%, specificity of 94%, accuracy of 91%, positive predictive value of 94% and negative predictive value of 88%. The T/L SUV(max) ratio was 1.0 +/- 0.2 for adrenal benign lesions and 4.5 +/- 3.0 for adrenal malignant lesions. And T/L SUV(max) ratio cut-off value of 1.8 corresponded to a sensitivity of 85%, specificity of 100%, accuracy of 91%, positive predictive value of 100% and negative predictive value of 83%. CONCLUSIONS: FDG-PET/CT with additional SUV(max) analysis improves the diagnostic accuracy of adrenal lesions in cancer patients.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/patologia , Fluordesoxiglucose F18 , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Fluordesoxiglucose F18/metabolismo , Humanos , Fígado/metabolismo , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
14.
Neuroradiology ; 51(3): 145-50, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19037635

RESUMO

INTRODUCTION: We have occasionally seen ring-shaped lateral ventricular nodules <1 cm in diameter during routine brain magnetic resonance imaging (MRI). We investigated retrospectively clinical and MRI findings of the nodules. MATERIALS AND METHODS: Review of radiological records was performed for 39,607 patients who underwent brain MRI between January 2001 and April 2008. Nodules were assessed for number, location, shape, and signal intensity, which was determined based on the range of signal intensity from gray to white matter on T1- and T2-weighted imaging. Fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted imaging (DWI), contrast enhancement characteristics, and serial MRI changes of nodules were assessed when available. RESULTS: Nine of 39,607 patients (0.023%) showed the nodules. No symptoms associated with the nodules. Among the nine patients, 11 nodules were identified (one nodule in seven patients (77.8%) and two nodules in two patients (22.2%)). Location was limited to the roof of the body for six nodules (54.5%) and the frontal horn for five patients (45.5%). All nodules (100%) were round and isointense on T1- and T2-weighted imaging. On FLAIR imaging of eight nodules, six (75%) were hyperintense, and two (25%) were isointense. On DWI of seven nodules, all nodules (100%) were isointense. None of seven nodules (0%) examined using postcontrast MRI showed enhancement. None of eight nodules (0%) examined using serial MRI (range, 4-60 months) showed changes in morphology over time. CONCLUSION: These nodules were incidentally encountered and shared similar MRI features. Although pathological confirmation was lacking in our cases, these nodules may be of nonaggressive nature.


Assuntos
Neoplasias do Ventrículo Cerebral/diagnóstico , Neoplasias do Ventrículo Cerebral/epidemiologia , Achados Incidentais , Imageamento por Ressonância Magnética/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade
15.
Radiat Med ; 26(3): 151-5, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18683570

RESUMO

PURPOSE: Motion artifact is problematic in the diagnosis of Creutzfeldt-Jakob disease (CJD) because of dementia. The purpose was to compare the occurrence of this artifact between a diffusion-weighted (DW) magnetic resonance (MR) imaging sequence and conventional sequences. MATERIALS AND METHODS: Ten MR examinations comprising T2-weighted, T1-weighted, DW, and fluid-attenuated inversion recovery imaging in seven CJD patients were retrospectively evaluated. The occurrence of motion artifacts on each sequence were assessed, and the examination was classified into four groups as follows: group A, motion artifact not revealed on DW imaging but revealed on one or more other sequences; group B, revealed on DW imaging and one or more other sequences; group C, not revealed on any sequences; and group D, revealed on DW imaging but not on any other sequences. RESULTS: The 10 MR examinations were classified as eight group A (80%), one B (10%), one C (10%), and zero D (0%). CONCLUSION: Motion artifacts are likely to occur in any conventional imaging sequences in CJD, but the fast-imaging ability of DW imaging can reduce this artifact. The combination of an absence of motion artifact on DW imaging and the presence on conventional sequences may be one of the frequent findings of CJD.


Assuntos
Artefatos , Síndrome de Creutzfeldt-Jakob/diagnóstico , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Retrospectivos
16.
Ann Nucl Med ; 22(6): 513-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18670858

RESUMO

OBJECTIVE: The objective of our study was to evaluate diagnostic ability and features of quantitative indices of three modalities: uptake rate on norcholesterol scintigraphy, computed tomography (CT) attenuation value, and fat suppression on chemical-shift magnetic resonance imaging (MRI) for characterizing adrenal adenomas. METHODS: Image findings of norcholesterol scintigraphy, CT, and MRI were reviewed for 78 patients with functioning (n = 48) or nonfunctioning (n = 30) adrenal masses. The norcholesterol uptake rate, attenuation value on unenhanced CT, and suppression on in-phase to opposed-phase MRI were measured for adrenal masses. RESULTS: The norcholesterol uptake rate, CT attenuation value, and MR suppression index showed the sensitivity of 60%, 82%, and 100%, respectively, for functioning adenomas of <2.0 cm, and 96%, 79%, and 67%, respectively, for those of >or=2.0 cm. A statistically significant correlation was observed between size and norcholesterol uptake, and between CT attenuation value and MR suppression index. Regarding norcholesterol uptake, the adenoma-to-contralateral gland ratio was significantly higher in cortisol releasing than in aldosterone-releasing adenomas. CONCLUSIONS: The norcholesterol uptake rate was reliable for characterization of adenomas among adrenal masses of >or=2.0 cm. CT attenuation value and MR suppression index were well correlated with each other, and were useful regardless of mass size.


Assuntos
19-Iodocolesterol , Neoplasias das Glândulas Suprarrenais/diagnóstico , Adenoma Adrenocortical/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Magn Reson Med Sci ; 7(2): 73-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18603838

RESUMO

PURPOSE: We evaluated the ability of the PRESTO (principles of echo shifting with a train of observations) technique to reveal small veins and microbleeds in the human brain. MATERIALS AND METHODS: In an experimental study, we calculated contrast-to-noise ratio (CNR) between a cerebral parenchymal phantom and human venous blood using 3 sequences of 3-dimensional (3D)-PRESTO, 3D-gradient recalled echo (GRE), and 3D-GRE echo-planar imaging (EPI). Then, we examined 7 healthy volunteers and 5 patients with venous angiomas or traumatic brain injuries using the 3D-PRESTO technique. In volunteer studies, MR venographies were reconstructed from 10-mm, 15-mm, and 20-mm thickness data using the minimum-intensity-projection (MinIP) technique. Three radiologists identified deep brain venous anatomy and counted the visible left medullary veins. In clinical studies, we evaluated the lesion conspicuity of small venous diseases and microbleeds. RESULTS: In the phantom study, 3D-PRESTO showed the highest CNR. In all volunteer studies, the deep brain venous anatomy was readily identified in the MinIP images at each thickness. The mean numbers of counted left medullary veins were 5.1 for 10 mm, 5.9 for 15 mm, and 6.7 for 20 mm in the MinIP images. The difference was significant between 10-mm and 20-mm MinIP images (P=0.02). In patient studies, abnormal small veins and microbleeds were clearly revealed. CONCLUSION: High-resolution MR venography using 3D-PRESTO technique can clearly depict small veins and microbleeds in the human brain.


Assuntos
Algoritmos , Veias Cerebrais/anatomia & histologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Humanos , Masculino , Flebografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
AJR Am J Roentgenol ; 190(6): W323-6, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18492873

RESUMO

OBJECTIVE: The purpose of our study was to evaluate whether simultaneous injection into cubital veins bilaterally at one half of the standard injection rate achieves similar hepatic and aortic enhancement on MDCT as the conventional injection rate into a single cubital vein. MATERIALS AND METHODS: Thirty-two patients underwent multiphase MDCT because they were suspected of having a hepatic tumor. Patients were assigned to one of the following two groups: group A, 100 mL of 370 mg I/mL of contrast medium injected into a unilateral cubital vein (one-route) via a 20-gauge cannula at a rate of 4 mL/s; or group B, 50 mL of contrast medium injected into the cubital veins bilaterally (two-route) via 24-gauge cannulas at 2 mL/s. Peak contrast enhancement of the liver and abdominal aorta for groups A and B was measured using regions of interest and compared; arrival time of the contrast media was also compared using a bolus-tracking system. Analysis was performed using Wilcoxon's signed rank test. RESULTS: Peak aortic enhancement of groups A and B was 367 +/- 67 H and 361 +/- 113 H (p = 0.61, not significant), respectively, and peak hepatic enhancement of groups A and B was 56 +/- 11 H and 56 +/- 16 H (p = 0.88, not significant), respectively. Mean arrival time to the aorta of group B (19.4 +/- 3.4 seconds) was significantly later compared with that of group A (15.5 +/- 3.5 seconds) (p = 0.005). CONCLUSION: The slower two-route injection produced the same aortic and hepatic enhancement as the faster one-route method with faster injection, but the arrival time of the contrast medium was later using the two-route method.


Assuntos
Aortografia/métodos , Meios de Contraste/administração & dosagem , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga , Feminino , Humanos , Injeções Intravenosas/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...